Table Top Front Loading Autoclave Manufacturer,Supplier and Exporter
Product Code : SEL-A-11615
Quick Answer: This front-loading table-top autoclave runs completely automatically, with preset instrument, liquid and rubber programmes and a manual programme that can add pre-vacuum and post-vacuum stages.
Last updated: October 2026
Key Features
- Table-top, front-loading design with a seamless chamber
- Completely automatic operation with error messages
- Digital and analogue pressure displays
- Digital timer for wet and dry cycles
- Water drains automatically to a reservoir tank after the cycle
- Instruments can be taken out of the chamber even after an electricity failure
Technical Specifications
| Specification | Value |
|---|---|
| Instrument programme (metallic devices) | 134 °C, 4 minutes, dry time 15 minutes |
| Liquid programme | 121 °C, 20 minutes, dry time 15 minutes |
| Rubber programme (rubber and plastic) | 121 °C, 20 minutes, dry time 15 minutes |
| Manual programme temperature | 121 to 134 °C |
| Manual programme time | 1 to 60 minutes, dry time 1 to 60 minutes |
| Manual programme vacuum | Pre-vacuum and post-vacuum can be set |
About This Product
Sized for a table top, this autoclave loads from the front and handles its cycle automatically, showing error messages on the display. Three preset programmes cover metallic instruments, liquids, and rubber and plastic items, while a manual programme lets the user set temperature, time, dry time and vacuum stages. At the end of a cycle the water drains to a reservoir tank, and instruments can still be removed from the chamber if the electricity fails. Buyers in the Maldives, Mauritius, Morocco, Kenya and Papua New Guinea can send an export enquiry for the Table Top Front Loading Autoclave.
Frequently Asked Questions
What programmes does this table top autoclave offer?
An instrument programme for metallic devices at 134 °C for 4 minutes, a liquid programme at 121 °C for 20 minutes, and a rubber programme for rubber and plastic at 121 °C for 20 minutes, each with a 15-minute dry time, plus a manual programme.
What can be set in the manual programme?
Pre-vacuum and post-vacuum, a temperature from 121 to 134 °C, a time of 1 to 60 minutes and a dry time of 1 to 60 minutes, as the user requires.
Can instruments be removed during a power cut?
Yes. Instruments can be taken out of the chamber even after the electricity fails.
Related: Autoclaves, Fully Automatic Autoclave, Double Wall Autoclave With Vacuum, Portable Steam Autoclave (Semi Automatic).
For a quotation on the Table Top Front Loading Autoclave, contact School Educational Instrument.